View Issue Details

IDProjectCategoryView StatusLast Update
0000717T99X171.00 SKB EagleHWpublic2019-05-17 11:09
Reporter(ALTech) SB ParkAssigned To(RD) Fu-chiang YoungDue Date2019-05-17 00:10
PriorityimmediateSeveritys1-catastrophicReproducibilityN/A
Status closedResolutionfixed 
Summary0000717: [DVT HW Validation] IR TEST (distand, angle, 3 wavelength, response time)
DescriptionHi Sean
according to your DVT schedule, this test 05/09~05/13
please update the report until due date
TagsNo tags attached.
Attach Tags

Users monitoring this issue

User List (ALTech) BY Lee , (ALTech) Jewoo Lee , (ALTech) Juyoung Park , (ALTech) SY Yoon , (HW) Sean Chiang , (RD) Fu-chiang Young

Activities

(HW) Sean Chiang

2019-05-14 01:10

developer   ~0002504

Hi Fu-Chiang,
Please update DVT build IR test report to Mantis. Thanks.

(RD) Fu-chiang Young

2019-05-14 08:13

developer   ~0002508

Hi SB,
Here is the IR test report.
The test result is pass.
Please refer to attached file.
Thank you.

(ALTech) SB Park

2019-05-14 08:27

developer   ~0002510

Hi Sean, Fu-chiang
Thank you for your report and Good job.
but It is also draft version. I mentioned at other mantis ID, I have no time to organize the draft version.
So please organize the report (HWQA format is very good)

(ALTech) SB Park

2019-05-14 08:42

developer   ~0002512

Hi Sean, Fu-chiang
SKB use the model name "BFX-AT100". please change T99X171.00 to BFX-AT100.
And there is no F/W version. please insert F/W

(HW) Sean Chiang

2019-05-14 17:04

developer   ~0002517

Hi SB,
We only remain 3 weeks for DVT testing, so the schedule is tight for us as well.
My idea is let us finish all the test items first then do the report format adjustment later on.

(ALTech) SB Park

2019-05-14 17:37

developer   ~0002519

Hi Sean.
I agree to your idea.
but In my experience of EVT report gathering, many EVT report have not be written correctly. I took very much time to review the EVT report.
(Please do not get me wrong, I don't blame you. You and your member have a great effort for EVT HW validation)
If I don't need to review or check DVT report, I support to your suggestion deeply.

(RD) Fu-chiang Young

2019-05-14 20:30

developer   ~0002522

Hi SB,
The updated report is as attached file.
Thank you.

(ALTech) SB Park

2019-05-14 21:14

developer   ~0002525

Hi Fu chiang.
thank you for updating report.
good job. the report format is better.
1. but the model name should be changed. BFX-AT100.
2. and Page1 the S/N is empty. please insert the serial no.

(RD) Fu-chiang Young

2019-05-15 09:03

developer   ~0002527

Hi SB,
Due to T99X171 is FXN project code, and we use it to manage our document.
But we still update the report and please refer the attached file.
Thank you.

(ALTech) SB Park

2019-05-15 09:23

developer   ~0002528

Hi. Fu-chiang, Sean
perfect report. thank you very much.

(ALTech) SB Park

2019-05-17 11:09

developer   ~0002552

Hi Sean
according to ID720, you mentioned to IR test. I accept and this ID will be closed
-----------------------------------------------------
As per discussion in weekly meeting, I will waive the IR response time test since there is no layout changes for IR circuitry in DVT build.
 Also, the 3 wavelength test should already be covered in IR range test report. Please check the IR range test w/ desk lamp on.
-----------------------------------------------------

Issue History

Date Modified Username Field Change
2019-05-13 23:13 (ALTech) SB Park New Issue
2019-05-13 23:13 (ALTech) SB Park Status new => assigned
2019-05-13 23:13 (ALTech) SB Park Assigned To => (HW) Sean Chiang
2019-05-13 23:14 (ALTech) SB Park Issue Monitored: (ALTech) Juyoung Park
2019-05-13 23:14 (ALTech) SB Park Issue Monitored: (ALTech) SY Yoon
2019-05-13 23:14 (ALTech) SB Park Issue Monitored: (ALTech) Jewoo Lee
2019-05-13 23:14 (ALTech) SB Park Issue Monitored: (ALTech) BY Lee
2019-05-14 01:09 (HW) Sean Chiang Issue Monitored: (RD) Fu-chiang Young
2019-05-14 01:10 (HW) Sean Chiang Assigned To (HW) Sean Chiang => (RD) Fu-chiang Young
2019-05-14 01:10 (HW) Sean Chiang Note Added: 0002504
2019-05-14 08:13 (RD) Fu-chiang Young File Added: T99X171.00 IR range test_20190506_V015.xls.pdf
2019-05-14 08:13 (RD) Fu-chiang Young Note Added: 0002508
2019-05-14 08:27 (ALTech) SB Park Note Added: 0002510
2019-05-14 08:42 (ALTech) SB Park Note Added: 0002512
2019-05-14 08:42 (ALTech) SB Park Description Updated
2019-05-14 17:04 (HW) Sean Chiang Note Added: 0002517
2019-05-14 17:37 (ALTech) SB Park Note Added: 0002519
2019-05-14 20:30 (RD) Fu-chiang Young File Added: T99X171T00 V015_IR range test_20190506_V1.pdf
2019-05-14 20:30 (RD) Fu-chiang Young Note Added: 0002522
2019-05-14 21:14 (ALTech) SB Park Note Added: 0002525
2019-05-15 09:03 (RD) Fu-chiang Young File Added: T99X171T00 V015_IR range test_20190506_V2.pdf
2019-05-15 09:03 (RD) Fu-chiang Young Note Added: 0002527
2019-05-15 09:23 (ALTech) SB Park Note Added: 0002528
2019-05-17 01:03 (HW) Sean Chiang Issue Monitored: (HW) Sean Chiang
2019-05-17 11:09 (ALTech) SB Park Note Added: 0002552
2019-05-17 11:09 (ALTech) SB Park Status assigned => closed
2019-05-17 11:09 (ALTech) SB Park Resolution open => fixed